dc.description.abstractA wearable healthcare monitoring unit that integrates various technologies was developed to provide patients with the option of leading a healthy and independent life without risks or confinement to medical facilities The unit consists of various sensors integrated to a microcontroller and attached to the patient s body reading vital signs and transmitting these readings via a Bluetooth link to the patient s mobile phone Short Messaging Service SMS is incorporated in the design to alert a physician in emergency cases Additionally an application program running on the mobile phone uses the internet to update at regular intervals the patient records in a hospital database with the most recent readings To reduce development costs the components used were both off the shelf and affordable
dc.identifier.urihttp://dx.doi.org/10.1504/IJEH.2009.026273
dc.identifier.urihttps://lib.digitalsquare.io/xmlui/handle/123456789/3966
dc.relation.uriInternational journal of electronic healthcare
dc.titleDesign and implementation of a wearable healthcare monitoring system.en
dcterms.abstractA wearable healthcare monitoring unit that integrates various technologies was developed to provide patients with the option of leading a healthy and independent life without risks or confinement to medical facilities The unit consists of various sensors integrated to a microcontroller and attached to the patient s body reading vital signs and transmitting these readings via a Bluetooth link to the patient s mobile phone Short Messaging Service SMS is incorporated in the design to alert a physician in emergency cases Additionally an application program running on the mobile phone uses the internet to update at regular intervals the patient records in a hospital database with the most recent readings To reduce development costs the components used were both off the shelf and affordable
dcterms.contributorSagahyroon, Assim
dcterms.contributorRaddy, Hazem
dcterms.contributorGhazy, Ali
dcterms.contributorSuleman, Umair
dcterms.identifierhttp://dx.doi.org/10.1504/IJEH.2009.026273
dcterms.relationInternational journal of electronic healthcare
dcterms.titleDesign and implementation of a wearable healthcare monitoring system.en
Files
Collections